spacer
spacer
 
 

ISO Certification
FocusLab is ISO 9001:2015 certified.
Click above logo to view a copy of ISO 9001:2015 certificate.

 

 

Accept credit cards
certified bank logo
Payment Gateway from Kasikorn Bank
securely with K-Payment Gateway.


 
TH  | EN
 
Application

Plain Bearing (journal , sleeve,etc) -lubricating compartment /system
Rolling Element Bearing (Roller ,etc) -lubricating compartment / system


 

Recommendation (Regular Routine Oil Analysis)
Sampling Quantity
Sampling Location/Point

Sampling Frequency
Oil Analysis Report

Turaround Service Time
Example of Oil Analysis Report

Technical Articles and Case Study Related to this application

Recommendation (Regular Routine Oil Analysis)

Basic Package

BearingCheck894

Premium Package

BearingCheck 824


All Tests below are for BearingCheck ™ 894

Wear Metal Elements -Condition

  • Fine Wear Metal - 18 elements, ASTM D6595 or ASTM D5185
  • RFS Coarse Wear Metal - 11 elements, ASTM D6595
  • Particle Quantifier Index (PQ Index), ASTM D8184

Oil Condition

  • Oil Condition ; oxidation, nitration, ASTM E2412M
  • Viscosity @ 40 °c or 100 °c, ASTM D445
  • Acid Number, ASTM D974

Contamination

  • Report with interpretation


All Tests below are for BearingCheck ™ 824

Wear Metal Elements - Condition

  • RDE - AES Wear Metal - 18 elements, ASTM D6595
    or ICP - AES Wear Metal - 18 Elements, ASTM D5185
  • RFS Coarse Wear Metal - 11 elements, ASTM D6595
  • Particle Quantifier Index (PQ Index), ASTM D8184
  • Ferrographic Analysis, ASTM D7690

Oil Condition

  • Oil Condition; oxidation, nitration, ASTM E2412M
  • Viscosity @40°c or 100°c, ASTM D445
  • Acid Number, ASTM D974

Contamination

  • Report with interpretation


Highlight FocusLab's unique testing
in BearingCheck™ 894

Highlight FocusLab's unique testing
in BearingCheck™ 824

 

Product Data & Service Sheet of BearingCheck™ 894 and BearingCheck™ 824

* Wrong oil contamination can be detected in case BASELINE data will be available

 

Note: The above recommended test package will be guideline, the suitable test package may be vary depend upon right application, environment severity, critical factor, machine age, and so on.

Test Description

Oil Sample Quantity: 100 ml.

Oil Sampling Location/Point

Sampling Frequency

Reports

LubeCheck™ Oil Analysis Report provide :-
  • Display an easy-to-read and understand.
  • Information for wear condition ,lubricant condition and contamination.
  • Interpretation and recommendation of the result . Option for Bilingual.
  • Color coded display of overall condition for present sample and history condition of previous sample.



  • Color coded problem highlights.
  • Provide new oil or reference oil for comparing result and as baseline.
  • Publish Alarm Limit range of the equipment and oil.
  • Comprehensive trending graph of most parameters.
  • LubeCheck™ Oil Analysis offers reporting options via internet, email and fax.


Turnaround Time Service

The report is typical available within 7-10 working days of sample receipt at FocusLab's labortory.

Examples of report

  • Bearing Report 1
  • Bearing Report 2

    Remarks: Oil samples (after completion of testing) will be retained in our laboratory for approx 60 days ,just in case of in-depth testing and/or any future purpose.

 

Technical articles and case study related to this application

 


Latest updates


Airbus Helicopters Approved Laboratory

Safran Approved Laboratory

ICML Certified Professional of FOCUSLAB Ltd.

 

cls
 


 

 




FOCUSLAB™, LubeCheck™, Double WearCheck™, TH2O Check™, VsPI™, GreaseCheck™, SkyCheck™, TurbineCheck™, HeatTransferCheck™, CoolantCheck™ are all trademarks of FOCUSLAB Ltd.

 

FOCUSLAB Ltd. © 2011 All rights reserved.